Vestibule Exception Air Curtains

ETA

The ETA unheated air curtain has been tested in accordance with ANSI/ AMCA 220 and meets the criteria for use as an exception to the vestibule requirement in Climate Zones 3 and above. The ETA is used to stop cold or warm air from entering a climate controlled environment and is designed for all retail, grocery and office entryways as well as other applications that typically would require a vestibule. This commercial line’s stainless steel construction, stainless steel intake screen, and 45 degree beveled edges give it a modern, pleasing look.
Heating
Unheated
Max Install Height
14'
Installation
Exposed
Incremental Widths
3' to 14'
View ETA Specs & Info

ETA-E

The ETA-E electrically heated air curtain has been tested in accordance with ANSI/AMCA 220 and meets the criteria for use as an exception to the vestibule requirement in Climate Zones 3 and above . The ETA-E is used to stop cold or warm air from entering a climate controlled environment and is designed for all retail, grocery and office entryways as well as other applications that typically would require a vestibule. This commercial line’s stainless steel construction, stainless steel intake screen, and 45 degree beveled edges give it a modern, pleasing look .
Heating
Electric
Max Install Height
14'
Installation
Exposed
Incremental Widths
3' to 14'
View ETA-E Specs & Info

ETA-HW

When requesting a quote for a Hot Water heated air curtain, please provide: • Specifics of water entering and exiting the air curtain. • Location for water supplies and returns (both on one side or one each side)
Heating
Hot Water
Max Install Height
14'
Installation
Exposed
Incremental Widths
3' to 14'
View ETA-HW Specs & Info

ETA-ST

When requesting a quote for Steam heated air curtain, please provide: • Specifics of steam entering and exiting the air curtain. • Location for steam supplies and returns (both on one side or one each side)
Heating
Steam
Max Install Height
14'
Installation
Exposed
Incremental Widths
3' to 14'
View ETA-ST Specs & Info

CHA

The CHA unheated air curtain has been tested in accordance with ANSI/AMCA 220 and meets the criteria for use as an exception to the vestibule requirement in Climate Zones 3 and above. It is specifically designed to be dropped into the ceiling above customer entryways where a standard air curtain is not desired .
Heating
Unheated
Max Install Height
14'
Installation
Above Ceiling
Incremental Widths
3' to 12'
View CHA Specs & Info

CHA-E

The CHA-E electrically heated air curtain has been tested in accordance with ANSI/AMCA 220 and meets the criteria for use as an exception to the vestibule requirement in Climate Zones 3 and above. It is specifically designed to be dropped into the ceiling above customer entryways where a standard air curtain is not desired.
Heating
Electric
Max Install Height
14'
Installation
Above Ceiling
Incremental Widths
3' to 12'
View CHA-E Specs & Info

CHA-HW

The CHA-HW hot water heated air curtain has been tested in accordance with ANSI/AMCA 220 and meets the criteria for use as an exception to the vestibule requirement in Climate Zones 3 and above. It is specifically designed to be dropped into the ceiling.
Heating
Hot Water
Max Install Height
11'
Installation
Above Ceiling
Incremental Widths
3' to 12'
View CHA-HW Specs & Info

CHA-ST

The CHA-ST Steam heated air curtain has been tested in accordance with ANSI/AMCA 220 and meets the criteria for use as an exception to the vestibule requirement in Climate Zones 3 and above. It is specifically designed to be dropped into the ceiling.
Heating
Steam
Max Install Height
11'
Installation
Above Ceiling
Incremental Widths
3' to 12'
View CHA-ST Specs & Info